Resultado da pesquisa (1)

Termo utilizado na pesquisa Minho A.P.

#1 - Evaluation of the indirect fluorescent antibody test and modified agglutination test for detection of antibodies against Toxoplasma gondii in experimentally infected pigs

Abstract in English:

Minho A.P., Navarro I.T., Freire R.L., Vidotto O., Gennari S.M., Marana E.M. & Garcia J.L. 2004. Evaluation of the indirect fluorescent antibody test and modified agglutination test for detection of antibodies against Toxoplasma gondii in experimentally infected pigs. Pesquisa Veterinária Brasileira 24(4):199-202. Depto Medicina Veterinária Preventiva, Universidade Estadual de Londrina, Cx. Postal 6001, Londrina, PR 86050-970, Brazil. E-mail: italmar@uel.br The study determined the sensitivity and specificity of the indirect fluorescent antibody test (IFAT) and modified agglutination test (MAT) for anti-Toxoplasma gondii antibody detection by analyzing sera from 46 experimentally infected pigs. Values for sensitivity were 95.7% (confidence interval 95%: 84.0-99.2%) and for specificity 97.8% (confidence interval 95%: 87.0-99.9%) in both tests. There was an optimum agreement of results between IFAT and MAT evidenced by a Kappa test of 0.86. These results validate these tests for the detection of T. gondii infection in pigs. IFAT and MAT despite methodologies with different characteristics and readings have similar accuracy in pig serum samples.

Abstract in Portuguese:

Minho A.P., Navarro I.T., Freire R.L., Vidotto O., Gennari S.M., Marana E.M. & Garcia J.L. 2004. Evaluation of the indirect fluorescent antibody test and modified agglutination test for detection of antibodies against Toxoplasma gondii in experimentally infected pigs. Pesquisa Veterinária Brasileira 24(4):199-202. Depto Medicina Veterinária Preventiva, Universidade Estadual de Londrina, Cx. Postal 6001, Londrina, PR 86050-970, Brazil. E-mail: italmar@uel.br The study determined the sensitivity and specificity of the indirect fluorescent antibody test (IFAT) and modified agglutination test (MAT) for anti-Toxoplasma gondii antibody detection by analyzing sera from 46 experimentally infected pigs. Values for sensitivity were 95.7% (confidence interval 95%: 84.0-99.2%) and for specificity 97.8% (confidence interval 95%: 87.0-99.9%) in both tests. There was an optimum agreement of results between IFAT and MAT evidenced by a Kappa test of 0.86. These results validate these tests for the detection of T. gondii infection in pigs. IFAT and MAT despite methodologies with different characteristics and readings have similar accuracy in pig serum samples.


Colégio Brasileiro de Patologia Animal SciELO Brasil CAPES CNPQ UNB UFRRJ CFMV